Improving Efficiency in the SIUC Campus Chilled Water System Using Exergy Analysis

Improving Efficiency in the SIUC Campus Chilled Water System Using Exergy Analysis

4.11 - 1251 ratings - Source



This study evaluates the central chilled water system of the Southern Illinois University Carbondale campus, which consists of a primary-secondary-tertiary water distribution system cooled by two 12, 300 kW (3, 500 Rton) centrifugal chillers, each powered by a condensing steam turbine. Statistical and thermodynamic analyses of steady-state data characterize system performance with the goal of identifying opportunities to increase capacity utilization and reduce the unit cost of delivered chilled water. Chiller load is modeled as a function of wet-bulb temperature and hour of day. Secondary loop water flow rates are modeled and predicted from temperature measurements. A comprehensive exergy analysis is used to identify the sources and magnitudes of irreversibilities and to rationally cost these losses. Results show that the steam turbine is the largest source of exergy destruction in both chillers. Nevertheless, water distribution losses are the dominant exergy unit cost at low loads, while refrigeration cycle losses contribute most to costs at high loads. The results also demonstrate a significant cost advantage of a three-pass over a two-pass evaporator. Recommendations drawn from the study include conversion of the water distribution system to an all-variable-speed, direct-coupled configuration to eliminate mixing and unnecessary pumping, and controls upgrades such as automatic chilled water temperature reset based on building flow requirements and a more aggressive use of compressor speed for capacity control. Finally, the results suggest that the steam turbines should be replaced with variable-speed motors, however further study is required on the feasibility of utilizing the displaced steam load for cogeneration at the boiler plant.... in the Spring of 2006, there was very little data readily available to answer questions about the chiller systemsa#39; performance. ... PSO maintenance and engineering staff and from the field technician and service manager from the Carrier Corporation, ... In addition, many hours were spent making field observations, collecting manual data logs, and recording component ... As a result of a CFC-to- HFC refrigerant conversion project in 1999, many of the measurements used by the chilleranbsp;...


Title:Improving Efficiency in the SIUC Campus Chilled Water System Using Exergy Analysis
Author: Justin M. Harrell
Publisher:ProQuest - 2007
ISBN-13:

You must register with us as either a Registered User before you can Download this Book. You'll be greeted by a simple sign-up page.

Once you have finished the sign-up process, you will be redirected to your download Book page.

How it works:
  • 1. Register a free 1 month Trial Account.
  • 2. Download as many books as you like (Personal use)
  • 3. Cancel the membership at any time if not satisfied.


Click button below to register and download Ebook
Privacy Policy | Contact | DMCA