The high gas temperatures preclude the use of HEPA filters for contamination control, making the flame cutting ... The tool consists of a hydraulic cylinder that drives a wedge-shaped plug between two expandable guides (called feathers) inserted in the predrilled hole. ... Concrete may be separated at the fracture line using a backhoe mounted ram or similar equipment. ... Holes may be drilled from 1 to 3 ft (30 to 90 cm) apart to establish a fracture line for massive concrete sections.